Micro-Z ULSD Analyzer
High-precision analyzer for ultra-low sulfur diesel (ULSD).
Key Features:
- Highly accurate sulfur measurement (in ppm).
- Fast analysis with minimal sample preparation.
- User-friendly interface with comprehensive software.
- Robust and reliable for continuous operation.
- Compliant with ASTM and ISO standards.
ASTM, D2622, ISO, 20884, JIS, K 12541-7
Designed for ultra-low level sulfur analysis of diesel, petrol (gasoline) and other fuels, the Rigaku Micro-Z ULSD sulfur analyzer and wavelength dispersive X-ray fluorescence (WDXRF) instrument features a novel design that measures both the sulfur peak and the background intensity. The sulfur analyzer's ability to measure and correct for changes in background intensity delivers superior calibrations and enhanced real world precision. With a lower limit of detection (LLD) of 0.3 ppm S, Rigaku Micro-Z ULS sulfur-in-oil analyzer complies with ASTM 2622-10, ISO 20884 and JIS K2541-7 methods.
Features
Accessories
The following accessories are recommended for purchase in sequential order (see eStore):
1st Year: | Sample Cells Sample Cup Ring Film, Etnom®, 3um, 3″ Dia, 100 pcs Thermal printer for Micro-Z Printer Paper (Roll) for Thermal Printer SULFUR IN MINERAL OIL, ULSD, 5-100ppm |
2nd Year: | Sample Cells Film, Etnom®, 3um, 3″ Dia, 100 pcs Printer Paper (Roll) for Thermal Printer SULFUR IN MINERAL OIL, ULSD, 5-100ppm |
Remaining Parts: |
Specs
Instrument | • Wavelength dispersive X-ray fluorescence analyzer – Includes vacuum pump • Elemental range: sulfur (S), LLD = 0.4 ppm • Application: analysis of fuels for sulfur content • Single measurement position (std. 35 mm cup) |
|
Supported methods | • ASTM D2622-10, • ISO 20884 and JIS K2541-7 |
|
Excitation | • 40 kV Cr-anode X-ray tube • 40 W max power |
|
Detection | • Doubly curved RX-9 analyzing crystal • Sealed proportional counter • Fixed optics with switchable receiving slit – To select peak or background • Pulse height analyzer (PHA |
|
Atmosphere | • Sample analysis in air • Optics are under vacuum |
|
Environmental conditions | • Ambient temperatures 15 – 28°C • Relative humidity <75% non condensing • Vibration undetectable by human • Free from corrosive gas, dust, and particles |
|
Computer | • Embedded dedicated processor • Proprietary operating system |
|
Software | • Up to 10 calibrations • Up to 30 standards per calibration • Selectable analysis time (up to 900 s) • Drift correction • Pulse height analyzer (PHA) adjustment |
|
Userinterface | • LCD display • Embedded computer • Membrane keypad and navigation |
|
Options | • Thermal dot printer | |
Dimensions / Power | • Analyzer: 43x40x40 cm (17x16x16 inches) 50 kg (110) • Pump: 48x15x30 (19x6x12 inches) 23 kg (50 lbs) • 100-120 VAC, 15 A or 200-240 VAC, 10 A |
Downloads
Download our brochure for more details
Videos
Configuration
ASTM D2622 | |
AYA-62-99074 | Sample Cells for Micro-Z |
AYA-62-99020 | Film, Etnom, 3um, 3″ Dia |
AYA-62-99075 | Sample cup ring for Micro-Z |
AYA-62-99071AYA-62-99071 | Thermal printer for Micro-Z |
Tags
Related
eStore
You May Also Like
-
Cleaning wipes
$28.00 -
Data transfer software for Micro-Z
$1,795.00 -
Gas relief hole punch
$574.00 -
Printer Paper (Roll) for Thermal Printer
-
Sample Cells for Micro-Z
$623.59 -
Sample cup film, 7.6 ㎝ × 91.4m, (2.5μm)
$395.00 -
Sample cup ring for Micro-Z
$52.00 -
Sample film alignment
$73.00 -
Thermal printer for Micro-Z
$895.00