ERAFLASH S10
Advanced flash point tester, automated for 10 samples for highest efficiency.
- Safe and quick measurements
- Small sample volume required for up to 10 automated measurements
- Wide temperature range for diverse applications, ability of connecting to High Temperature Module (HTM) extension to increase the temperature range up to 420°C (788°F)
- Fast results with an easy-to-use touchscreen interface
- Portable and robust for field use
Key Features
ERAFLASH S10 is fully compliant with ASTM D6450, ASTM D7094, ASTM D5808, providing both standard method and refined methodology.
ERAFLASH S10 Fast screening test programs for unknown samples.
The ERAFLASH S10 is the first 10-position autosampler for flash point testing.
Temperature control range: 0 °C–200 °C (32 °F–390 °F) stand alone. No external cooling is required.Down to -25 °C (-13 °F) with water cooling / chiller
Up to 420 °C (788 °F) with optional High Temperature Module (EF01-HTM)
-40 °C–120 °C (-40 °F–248 °F) EF20 ERAFLASH LT model with external cooling
Easy view of various info. Straightforward & user-friendly operation. Display colours can be changed
The Eraflash S10 user has programmable methods. Any methods that have been saved to memory,
Easy operation with sample stage at the front.
ERAFLASH S10: specifies fuels, analyzing fresh andused lubricating oils, and bitumen testing. The small sample
volume also renders it ideal for the more expensive samples
such as flavors & fragrances, cosmetics, paints and varnishes
or even hazardous waste. Gasoline Analysis: oxygenates, aromatics, OCTANE boosters, RON, MON, AKI, RVPE, VLI, density and distillation properties …
Alarm Tracking All alarm messages are stored in the database together with the result. Automatically shuts off and the problem is reported by buzzer and display.Videos


Built-in 10-port autosampler
Ten samples.
One unattended run.
Introducing the ERAFLASH S10: augmented ultra-wide range flash point tester maximized for high-volume autosampling
The ERAFLASH S10 is a compact, safe, and reliable flash point tester covering an incredibly wide temperature range with a built-in 10-port autosampler. With a continuously closed cup design paired with unparalleled thermoregulation using Peltier elements, the ERAFLASH S10 ensures maximized safety and efficiency while subsequently testing up to ten samples in one run.
High-volume autosampling
Load the sequence.
Let S10 keep testing.
1–2 mL
Sample per test
Continuously closed cup design
With the distinct capability to incorporate both a high temperature and a low temperature module, this singular analyzer can cover a temperature range from −25 °C to 420 °C with only 1–2 mL of sample per test. To complete a test, the device produces an electric arc in a closed chamber to determine at which temperature the arc ignites the sample vapor, which is measured by the pressure change observed in ignition. The notable feature of the ERAFLASH S10 is the built-in autosampler, making it the ideal solution for unattended flash point testing.
Built for unattended flash point testing
Compliance / Correlation
Standards-ready.
High-volume capable.
ASTM D6450 · ASTM D7094
This device is fully compliant with ASTM D6450 and D7094 with a diverse array of correlation methods, making it the ideal solution for almost any flash point determination in both laboratory and on-the-go environments.
- 01
Temperature Range
−25 °C to 420 °C (−13 °F to 788 °F). Stand-alone range is 0 °C to 200 °C; the low end requires external cooling and the high end the optional High Temperature Module.
- 02
Flash Point + Flash/No Flash
Flash point corrected to sea level is displayed in units of temperature. In correlation tests: Flash versus No Flash determinations.
- 03
Pressure Change + Temperature
Largest pressure difference during the flash test. Live, expected, and corrected temperatures.
- 04
Unattended Throughput
Ten loaded samples in approximately 45 minutes, depending on temperature range.
Applications of the ERAFLASH S10
- Safety characteristic determination
- Transportation regulations compliance
- Appropriate storage requirements
- Aids in fire protection and investigation
Specs
| Available Test Methods | ASTM D6450, ASTM D7094 | |
| Pre-Programmed Correlation Methods to | Pensky Martens Closed Cup: ASTM D93, EN ISO 2719, DIN 51758, IP 34, JIS K2265 TAG Closed Cup: ASTM D56 Abel Pensky Closed Cup: ISO 13736, IP 170 Small Scale Closed Cup and Flash / No Flash methods: EN ISO 3679, EN ISO 3680, ASTM D3828 |
|
| Fuel Specifications (ASTM D7094) | ASTM D396, ASTM D975, ASTM D2880, ASTM D3699, ASTM D7467 | |
| Speed Tests | Fast screening test programs for unknown samples | |
| Sample Handling | 10 position autosampler | |
| PBT – Peltier Boost Technology | High speed heating & cooling -25 °C to 420 °C (-13 °F to 788 °C) with a single analyzer |
|
| CPT – Contamination Prevention Technology | Advanced electrode protection and self-cleaning ignition system to minimize cleaning and maintenance | |
| Combustion Graphics | Display of combustion characteristics for contamination analysis | |
| QuickCal | Dry Block Calibration with eralytics unique directly attached Temperature Calibration Block (EF01-TCB) | |
| Fuel Dilution Program | Automatic fuel dilution measurement for the analysis of used engine oils | |
| Temperature Range | 0 °C to 200 °C (32 °F to 390 °F) stand alone. No external cooling is required. Down to -25 °C (-13 °F) oven temperature with external cooling Up to 420 °C (788 °F) with optional High Temperature Module (EF01-HTM) |
|
| Temperature Stability | 0.1 °C (0.2 °F) | |
| Unattended Sample Troughput | 10 loaded samples within approximately 45 minutes (depending on temperature range) | |
| Sample Volume | 1 mL (ASTM D6450), 2 mL (ASTM D7094) | |
| Sample Cups | Nickle plated aluminium, stainless steel cups available upon request | |
| Display | Industry proven 8″ color touchscreen | |
| Languages | English, German, French, Spanish, Russian, Chinese Additional langages available upon request |
|
| Interfaces | Built-in PC with Ethernet, USB and RS232 interfaces Direct LIMS connectivity and output to printer or PC Optional input by external keyboard, mouse and barcode / QR-code reader |
|
| Remote Control | Remote service capability via Ethernet interface | |
| PC Software | ERASOFT RCS – remote control Windows software for multi-instrument remote control, convenient data transfer and result analysis | |
| Result Database | Over 100 000 detailed test reports stored in internal memory | |
| Alarm Tracking | All alarm messages are stored in the database together with the results | |
| Operating Conditions | Temperature range 10°C to 40°C Humidity up to 90% RH, non condensing |
|
| Power Requirements | Auto-switching 85-264 V AC, 47-63 Hz, max. 150 W (multi-voltage power supply) Field application: 12 V DC (vehicle battery) adapter available |
|
| Dimensions / Weight | 30 x 27 x 43 cm (11.8 x 14.6 x 16.9 in) / 14.5 kg (32 lb) |
Tags
Complete The Package
-
2D Barcode / QR Code scanner preconfigured for the use with eralytics products AYA-82-22333
-
Accessories kit ERAFLASH (EF10) (includes all items mentioned in the standard sc
-
Anti-vibration plate for vibration and disruption free mounting in a mobile labo
-
Brass eraser
-
Compact Printer
-
D6450 Sample cup standard
-
Disposable Pipettes
-
ERAFLASH sample temperature sensor
-
Ethernet cable for data exchange via Internet
-
FL250 Recirculating Cooler/Chiller from Julabo; temperature range 20C to 40C;
-
FL300 Recirculating Cooler/Chiller from Julabo; temperature range 20C to 40C;
-
High Temperature Module: 200 to 420°C (390 to 788°F)Temperature extension
-
Laboratory Cleaning Brushes for Electrodes
-
Lead Corrosion Beaker
-
Oven temperature sensor
-
Pipette Tips (96 pcs.) for EF01-A012 1ml automatic pipette
-
Protective film for touch display (5 pcs) (for instruments with 8" display)
-
Replacement Conductivity Probe
-
Round Cooling Block for Sample Cups
-
Standard D7094 2mL Sample Cup
-
Stirring Magnet
-
Stylus for data entry via touch display
-
Temperature calibration block for fast on-site cal
-
USB - RS232C Converter
-
Vacuum pump (as per Section 6.1.12) (220 volt)