Aquamax KF PRO OIL
High-performance titrator for water content analysis in oils.
Key Features:
-
- Precise and repeatable water content measurement.
- User-friendly software with data logging.
- Suitable for a wide range of oil types.
- Durable and easy-to-maintain design.
- Compliant with industry standards.
ASTM, D1533, D4928, D6304, D7933, D7995, IP, 356, 358, 438, ISO, 10101-3, 12937, 10337
The gas extraction is the ideal method to detect moisture in oil samples and viscous substances. For this analysis, the Oil Module is combined with the Basic Module of AQUA 40.00.
Trace amounts of water can be measured with the special heating chamber for oils. The sample has no contact with the reagent. Therefore the consumption of reagent is low.
Using an appropriate syringe, oil sample is injected through the septum into heating oven without a contamination of device. It is possible to apply sample volumes from 0.01 up to
20 mL depending on water content.
The sample can be heated out with temperature program or isothermal heating. The measurement is carried out in the measuring cell with titration method according to Karl Fischer. After analysis, the used oil sample flows out through a valve.
With closed-loop carrier gas circulation, any additional gas drying is no longer necessary: the carrier gas is continually titrated to dryness within the closed loop. The total dryness of the gas enhances the moisture desorption from the sample. Moreover, sensitive samples can be heated out very gently. Degradations and side reactions are eliminated.
You can distinguish between various types of bonded water when you use heating with temperature program.Request a quote for this oil module online.
Features
Accessories
The following accessories are recommended for purchase in sequential order (see eStore):
1st Year: | No spare parts are required |
2nd Year: | No spare parts are required |
Remaining Parts: |
Specs
Test standards | ||
Applications | Analysis of liquefied gases: LPG, LNG Propane, propene, butane, butene, butadiene Ethylene oxide Chlorinated hydrocarbons, e. g. methylene chloride,ethylene chloride, vinyl chloride Refrigerants: halogenated hydrocarbons ***Analysis of permanent gases, e. g. natural gas,technical gases and mixtures of test gases |
|
Measuring method | Coulometric Titration | |
Sample | Pressurized gas sample (LNG, LPG) | |
Sample cylinder | 0.5 liter pressurized bottle or directly from the gas line | |
Pressure reducer | Internal (with heating element ) | |
Sample loop | 500 ml (gas) | |
Rinsing and dosing | 0…15 steps for each, adjustable | |
Type of result | μg, ppm (gas volume) by using the formula generator | |
Measuring range | 1 … 10,000 ppm | |
Resolution | 0.1 ppm. | |
Detection limit | 1 ppm | |
Car adapter | 12 V | |
Dimensions | 38 x 45 x 20 cm (L x H x D) | |
Weight | 8 kg |
Downloads
Download our brochure for more details
Tags
Related
eStore
You May Also Like
-
Cou-Lo Formula Reagents
-
Complete set LDC glassware
$4,675.98 -
Gas Analysis Kit
-
Stirrer Bar
$20.78 -
Luer Needle Pair (17 & 19 gauge, one each)
$44.88 -
Powder Sampler
$54.00 -
Molecular Sieve
$124.69 -
Glassware Box (Plastic)
$37.00 -
Gas Tight Syringe 0.25ml
$189.00 -
Gas Tight Syringe 1.0ml
$187.04 -
Gas Tight Syringe 5.0ml
$187.04 -
Pack Injection Septa (Pack of 10)
$93.52 -
Desiccant Tube LDC cap
$197.43 -
Electrode Lead
$197.43 -
Generator Electrode frit LDC
$2,094.40 -
Titration Vessel LDC
$1,652.18 -
Detector Electrode LDC
$1,506.70