Eraflash X Pensky-Martens Analyzer
Flash point tester with advanced Peltier Boost Technology (PBT).
- Small sample volume required
- Wide temperature range for various applications, ability to test for temperatures up to 370 °C (689 °F) without connecting to high temperature module (HTM)
- Fast results and easy-to-use interface
- Portable and suitable for on-site testing
- Compliant with standards, safe and quick measurements
Key Features
ERAFLASH Flashpoint Tester is fully compliant with ASTM D396, D975, D2880, D3699, providing both standard method and refined methodology.
All eralytics analyzers use an intuitive menu structure that is easy to navigate. Samples need no prior preparation and measurements are done fully automated.
A direct out-of-the-box connection to LIMS (Laboratory Information Management System) is established with a standard Ethernet cable.No extra software or PC are necessary.
The small footprint of the eralytics instruments makes them the first choice for use in the lab and on-site.
The Eralytics units are all lightweight and built with an integrated carrying handle, they are versatile and ideally suited for mobile applications as well.
All Eralytics analyzer results are displayed immediately after the test on their large and user-friendly color touch screen.
Cleaning after measurements often took time and involved maintenance activities or replacing sensors or other elements of the chamber assembly. The ERAFLASH is different. Its innovative CPT-Contamination Prevention Technology TM, a combination of an advanced electrode protection and self-cleaning ignition system, reduces cleaning & maintenance to an absolute minimum.
The ERAFLASH’s innovative PBT – Peltier Boost Technology TM, a patented eralytics innovation, allows for previously unmatched heating and cooling rates. Paired with the conveniently small size of the sample cup this analyzer allows turnaround times that are significantly shorter than those offered by all other instruments available on the market.Videos

Compact, safe, and robust
Wide-range flash point.
Smallest footprint.

7.2 kg
15.9 lb · Field + lab
19.6 × 20.4 × 31.7 cm (7.7 × 8.0 × 12.5 in)
Introducing the ERAFLASH X: compact ultra-wide range flash point tester with a robust design
The ERAFLASH X is a compact, safe, and robust flash point tester covering an incredibly wide temperature range, designed to operate in field and lab environments. With a continuously closed cup design and three patented designs of Peltier Boost Technology (PBT), Contamination Prevention Technology (CPT), and Peltier separation, the ERAFLASH X ensures maximized safety and efficiency.
Robust by design
Three patented systems.
One compact analyzer.
- PBT
Peltier Boost Technology
High-speed heating and cooling across the full measuring range.
- CPT
Contamination Prevention Technology
Advanced electrode protection and a self-cleaning ignition system that minimize cleaning and maintenance.
- PS
Peltier separation
Separated Peltier stages for stable thermoregulation in a smaller housing.
The ERAFLASH X analyzer can cover a temperature range from 18 °C to 370 °C (64 °F to 689 °F) with only 1–2 mL of sample per test, without a High Temperature Module (HTM) or any external device. To complete a test, the device produces an electric arc in a closed chamber to determine at which temperature the arc ignites the sample vapor, which is measured by the pressure change observed in ignition. Another feature of the ERAFLASH X is the built-in unknown sample screen test, which can quickly cover a wide range of temperatures to hone in on the specific flash point of unidentifiable samples or samples with unknown flash points.
Compliance / Correlation
Portable enough for field.
Precise enough for lab.
ASTM D6450 · ASTM D7094
This device is fully compliant with ASTM D6450 and D7094 with a diverse array of correlation methods, making it the ideal solution for almost any flash point determination in both laboratory and on-the-go environments.
- 01
Temperature Range
18 °C to 370 °C (64 °F to 689 °F), with no High Temperature Module or external cooling required.
- 02
Flash Point + Flash/No Flash
Flash point corrected to sea level is displayed in units of temperature. In correlation tests: Flash versus No Flash determinations.
- 03
Pressure Change + Temperature
Largest pressure difference during the flash test. Live, expected, and corrected temperatures.
Applications of the ERAFLASH X
- Safety characteristic determination
- Transportation regulations compliance
- Appropriate storage requirements
- Aids in fire protection and investigation
Specs
| Available Test Methods | ASTM D7094, IP 620 | |
| Fuel Specifications | ASTM D396, D975, D2880, D3699, D7467 | |
| PBT – Peltier Boost Technology® | High speed heating and cooling | |
| CPT – Contamination Prevention Technology™ | Advanced electrode protection and self-cleaning ignition system to minimize cleaning and maintenance | |
| QuickCal™ | In-situ calibration with eralytics unique calibration cups without the need of dismantling the instrument | |
| Fuel Dilution Program | Automatic fuel dilution measurement for the analysis of used engine oils | |
| Temperature Range | 18 °C to 370 °C (64 °F to 689 °F) | |
| Temperature Stability | 0.1 °C (0.2 °F) | |
| Turnaround Time | up to 5 tests per hour | |
| Sample Volume | 2 mL | |
| Reproducibility | R = 3.2 °C for diesel fuel at 60 °C (ASTM D93: R = 4.3 °C) R = 5.6 °C for lube oil at 200 °C (ASTM D93: R = 14.2 °C) |
|
| Result Database | Over 100 000 detailed test reports stored | |
| PC Software | ERASOFT RCS – Windows® software for convenient data transfer and result analysis | |
| Remote Control | Remote service capability via Ethernet | |
| Interfaces | Built-in PC with Ethernet, USB, and RS232 interfaces, Wi-Fi via USB dongle Direct LIMS connectivity via LAN and output to printer or PC |
|
| Display | Industry proven 5.7“ multilingual color touchscreen | |
| Languages | English, German, French, Spanish, Japanese, Chinese; additional langages available upon request | |
| Power Requirements | Auto-switching 85 – 264 V, AC 47 – 63 Hz, max 150 W, Field application: optional 12 V DC adapter | |
| Operating Conditions | Temperature range 10°C to 40°C, Humidity up to 90% RH, non-condensing | |
| Dimensions & Weight | W x D x H = 19.6 x 20.4 x 31.7 cm (7.7 x 8.0 x 12.5 in); 7.2 kg (15.9 lbs) |
Tags
Complete The Package
-
Brass eraser
-
Case latch
-
Ceramic
-
D6450 Sample cup standard
-
DC Adapter
-
Disposable Pipettes
-
ERAFLASH
-
ERAFLASH S10
-
ERAFLASH sample temperature sensor
-
Eralytics Flashpoint Cooling Cup
-
Glass syringe 20 ml
-
Laboratory Cleaning Brushes for Electrodes
-
Oven temperature sensor
-
Peltier element
-
Protective film for touch display
-
Sample cup carrier
-
Standard D7094 2mL Sample Cup
-
Stirring Magnet
-
Stylus for data entry via touch display