Refrigerated Baths for Manual Testing of Cloud Point, Pour Point, and Cold Filter Plugging Point of Petroleum Products

Methods:
ASTM, D97, D2500, D5853, IP, 15

Login or Register to buy or

[request_quote_button]

A wide variety of refrigerated water bath models are available with working temperature ranges from 48 to -69 C to test cloud point, pour point, and cold filter plugging point of petroleum products. Each multi-bath unit conforms to ASTM D97 pour point and ASTM D2500 cloud point test methods and related methods. Each stainless steel liquid bath has its own digital indicating PID temperature controller with 0.1 C resolution, providing temperature stability of 1.5 C. The baths of select models are agitated for improved temperature stability (0.5 C) and uniformity, making them suitable for ASTM D6371 (or IP309) cold filter plugging point test with the addition of the CFPP kit (see options tab).

Each refrigerated water bath comes equipped with 4 metal test jackets, 4 cork rings, 4 O-rings, and 4 cork stoppers for the thermometer (test tube is available separately). All units are mechanically refrigerated using ozone friendly non-CFC and non-HCFC refrigerants, making the instruments a sustainable choice in petroleum testing.

Features

features__astm compliantRefrigerated Baths for Manual Testing of Cloud Point, Pour Point, and Cold Filter Plugging Point of Petroleum Products is fully compliant with ASTM D2500, ASTM D3117, ASTM D5853, ASTM D6371, ASTM D6422, ASTM D97, providing both standard method and refined methodology

Models

Accessories

The following accessories are recommended for purchase in sequential order (see eStore):

1st Year: Test Jar (4 or 8 per test temperature bath), ea.<br />
O-Ring (one per test jar), per dozen<br />
Cork Stopper (one per test jar), per dozen<br />
Cork Disc (one per copper test jacket), per dozen
2nd Year: Insulating Sponge Cover (one per test temp. bath), ea.<br />
Metal Weight (one per copper test jacket), ea
Remaining Parts:

Specs

Test Method Compliance   ASTM D97, D2500, D3117, D5853, D6371, 
D6422, IP309, ISO 3015, ISO 3016
Temperature range   +48° to -69°C
Temperature stability    of ±1.5°C
Temperature control   Digital Indicating, 0.1ºC Resolution Temperature Controller
Sample capacity   4 test positions  
Bench / Floor model   Bench model 
Voltage / Current    115V or 220V
Frequency   50 or 60Hz 
Weight    64 kg (142 lbs)
Dimensions   62 x48x65 cm  (25×19 x26  inches)
Shipping weight    
Dimensions with crate    


AYALYTICAL EXCLUSIVE SERVICES

ISO OEM 17025 Certified

ISO 17025

Our Service Center has been ISO Accredited for Competence of Calibration.

AYALYTICAL EXCLUSIVE SERVICES  

1-3 Days Service Turn Around

 

We are please to offer our 1-3-day service turn around from our Ayalytical Service department.

AYALYTICAL EXCLUSIVE SERVICES

Application Support

 

We are pleased to offer our expertise in various disciplines including Physical Properties, Elemental and Compositional.

AYALYTICAL EXCLUSIVE SERVICES

Dedicated Support Lines

 

We are pleased to offer our On-Site trainings and service calls for our Ayalytical partners.